Duration: Heater
Set the length of time (minutes) the heaters stay On at full power
(100%) once the computer detects a quick rise in temperature
(
DeltaT
value, see above).
The default value is 5 minutes.
Note: The heaters may turn Off before the timer has expired if a
temperature reading indicates the computer is warm enough
or you manually turn Off the heaters by tapping the heater icon
once.
Low battery threshold
Set a low battery charge threshold (%) that triggers the computer to
turn Off the heaters to conserve battery power.
The default value is 25%.
Heater enabled temperature
Set the temperature (°C) that the computer must fall to before the
system determines cold storage entry and heater use. Once this
temperature is detected, the
Chill time
starts.
Chill time
Set the time limit (minutes) for how long the computer must remain
at or below the defined
Heater enable temperature
before the
system initiates one of the following actions:
•
If in
Automatic
mode and
Preemptive Heating
is disabled,
the system turns the heaters On when a cold storage exit is
detected (see
DeltaT
value).
•
If in
Automatic
mode and
Preemptive Heating
is enabled,
the system starts the
Preemptive Delay Time
.
Note: If you remove the computer from cold storage before the Chill
time expires, the system does not turn On the heaters, saving
battery power.
Preemptive Heating
Enable or disable
Preemptive Heating
(pre-heating) when
Automatic
mode is enabled. Tap the check box to toggle the feature
On or Off.
Preemptive Duty Cycle
Set the percentage of time that the heaters are on during
Preemptive Heating
.
Preemptive Delay Time
Set the length of time (minutes) that the computer waits after the
Chill time
has expired before activating the low power pre-heat
window feature.
Manual/Automatic
Tap the button to switch between
Automatic
mode or
Manual
mode. To learn more about the modes, see
Duration: Scanner heater
Set the length of time (seconds) that the scanner window heater is
cycled on.
Duration: LCD heater
Set the length of time (seconds) that the touch screen heater is
cycled on.
Fast monitoring interval
Set sampling interval time (seconds) used once the computer
detects cold storage entry. Cold storage entry is defined by the
Heater enabled temperature
.
Slow monitoring interval
Set sampling interval time (seconds) used once the computer
detects cold storage exit (defined by
DeltaT
value).
Disable temperature
Set the temperature limit (°C) that triggers turning off the heater.
Blanking
Tap check box to enable or disable heater operation during
scanning.
Heater Setting
Description
Summary of Contents for CN80G Series
Page 1: ...CN80G Series Mobile Computer powered by Android User Guide ...
Page 4: ...iv CN80G Mobile Computer Series User Guide ...
Page 58: ...48 CN80G Mobile Computer Series User Guide ...
Page 70: ...60 CN80G Mobile Computer Series User Guide ...
Page 82: ...72 CN80G Mobile Computer Series User Guide ...
Page 110: ...100 CN80G Mobile Computer Series User Guide ...
Page 123: ......