CYLINDER HEAD
14-7
VALVE SPRING FREE LENGTH
Measure the free length of the valve spring.
If the measured length is less than the service limit,
replace the valve spring (page 14-4).
VALVE SPRING PERPENDICULARITY
Measure the valve spring perpendicularity.
If the measured perpendicularity is more than the
service limit, replace the valve spring (page 14-4).
PUSH ROD RUNOUT
Check both ends of the push rod (1) for wear.
Check the push rod for straightness.
If necessary, replace the push rod (page 14-4).
STANDARD:
30.5 mm (1.20 in)
SERVICE LIMIT:
29.0 mm (1.14 in)
SERVICE LIMIT:
1.5°
(1)