IGNITION SYSTEM
9-7
IGNITION PULSE GENERATOR
INSPECTION
Measure the resistance between the terminal (1) and
the ignition pulse generator base (2).
IGNITION COIL INSPECTION
PRIMARY SIDE
Measure the resistance of the primary coil by attaching
the ohmmeter leads to the ignition coil terminal and the
iron core.
IGNITION CONTROL MODULE LINE
INSPECTION
Remove the control panel (page 8-8).
Disconnect the 10P ignition control module connector
from the ignition control module.
Test the wire harness according to the table below. If it
is normal, check the ignition control module.
Unit:
Ω
Resistance:
294 - 359
Ω
(20°C/68°F)
(1)
(2)
Resistance:
0.684 - 0.836
Ω
2
Terminals
Circuit
Test and result
2 – GND
Oil level switch
Check for resistance to fan cover body. There should be no continuity
with correct engine oil level.
5 – GND
Exciter coil
Check for resistance to fan cover body. Resistance: 1.0 – 2.0
Ω
6 – GND
Ground
Check for continuity to fan cover body. There should be continuity.
7 – GND
Ignition pulse generator
Check for resistance to fan cover body. Resistance: 290 – 370
Ω
10 – GND
Primary coil
Check for resistance to fan cover body with the engine switch ON.
Resistance: 1.0 – 2.0
Ω
2
Summary of Contents for EU3000i Handi
Page 37: ...MEMO ...
Page 73: ...MEMO ...
Page 75: ...FUEL SYSTEM 6 2 FUEL SYSTEM TOOLS Float level gauge 07401 0010000 ...
Page 97: ...MEMO ...
Page 133: ...MEMO ...
Page 149: ...MEMO ...
Page 150: ...12 1 12 12 MUFFLER MUFFLER REMOVAL INSTALLATION 12 2 ...
Page 179: ...MEMO ...
Page 180: ...16 1 16 16 TECHNICAL FEATURES FRAME MADE OF MAGNESIUM 16 2 INDICATOR 16 3 ...
Page 185: ...MEMO ...
Page 193: ...MEMO ...