GENERATOR/CHARGING SYSTEM
8-3
GENERATOR SYSTEM TROUBLESHOOTING
No or Low AC Output
8
9
11
Viewed from terminal side
11
Viewed from terminal side
GENERATOR WIRE HARNESS
O
G r
FUSE
G r
(C type only)
C type only:
Either or both
lights ON
Abnormal
Abnormal
Both lights OFF
Normal
Normal
When the engine running check whether the
output indicator and the overload indicator lights
are ON.
Go to page 8-4
Check the engine speed at no load.
Specified engine speed:3,600 ± 100 rpm(ECO
throttle switch OFF)
Check the ECO throttle switch, and if no problem
can be found, perform Throttle Control System
troubleshooting (page 7-2 and 3).
Remove the inverter unit (page 8-7).
Measure the resistance between the terminals of
the sub coil 2P connector.
Resistance: 0.4 - 0.7
Ω
Check the harness connecting the inverter unit
and generator for an open or short circuit and for
proper connection.
Replace the inverter unit (page 8-7).
Replace or repair the generator wire
harness (page 8-10).
Replace the stator (page 8-10).
Normal
Abnormal
Check the fuse in the generator wire
harness, replace it if necessary.