GENERATOR/CHARGING SYSTEM
8-4
From page 8-3
Light is ON
Abnormal
Abnormal
Abnormal
Light OFF
Light is ON
Normal
Normal
Normal
Check whether the overload indicator light (red) is
ON.
Disconnect the AC receptacle. Verify that the
cooling air duct is not blocked and the generator
is not placed near a wall.
Correct the above problems, and restart the
engine.
Check the AC circuit protector (page 8-28).
*Equipped type only
Replace the inverter unit (page 8-7).
Replace the AC circuit protector (page 8-13).
Replace the AC receptacle (page 8-13).
Remove the inverter unit (page 8-7).
Measure the resistance between the terminals of
the main coil 4P connector.
Resistance:
No.2 (R) - No.3 (W): 0.6 - 1.1
Ω
No.3 (W) - No.4 (Bu): 0.6 - 1.1
Ω
No.2 (R) - No.4 (Bu): 0.6 - 1.1
Ω
Check the harness connecting the inverter unit
and generator for an open or short circuit and for
proper connection.
Replace the inverter unit (page 8-7).
Check the AC receptacle.
7
2
3
4
10
Viewed from terminal side
GENERATOR WIRE HARNESS
R
W
B u
2
3
4
10
Viewed from terminal side
Replace or repair the generator wire
harness (page 8-10).
Replace the stator (page 8-10).
Normal
Abnormal
Summary of Contents for EU3000i Handi
Page 37: ...MEMO ...
Page 73: ...MEMO ...
Page 75: ...FUEL SYSTEM 6 2 FUEL SYSTEM TOOLS Float level gauge 07401 0010000 ...
Page 97: ...MEMO ...
Page 133: ...MEMO ...
Page 149: ...MEMO ...
Page 150: ...12 1 12 12 MUFFLER MUFFLER REMOVAL INSTALLATION 12 2 ...
Page 179: ...MEMO ...
Page 180: ...16 1 16 16 TECHNICAL FEATURES FRAME MADE OF MAGNESIUM 16 2 INDICATOR 16 3 ...
Page 185: ...MEMO ...
Page 193: ...MEMO ...