TÜV-A 03 ATEX 0019X
♦
cbr2052a0600p_01
♦
36/29
6.4. V
OLUME MEASUREMENT
P40: - - ba Tank shape
ba
Tank shape
Parameters programmed
b0
Standing cylindrical tank domed shape bottom
(value of “b” as below)
P40
(b),
P41
01
Standing cylindrical tank with conical bottom
P41
,
P43
,
P44
02
Standing rectangular tank (with chute)
P41
,
P42
,
P43
,
P44
,
P45
b3
Lying cylindrical tank shape (value of “b” as below)
P40
(b),
P41
,
P42
04
Spherical tank
P41
Attention!
The value „a” determining the
shape of the tank should be
set first.
DEFAULT: 0
P41-45: Tank dimensions
Standing cylindrical
tank domed shape
bottom
a = 0
Standing cylindrical
tank with conical
bottom
a = 1, b = 0
Standing
rectangular tank
a = 2, b = 1
Lying cylindrical tank shape
a = 3
Spherical tank
a = 4, b = 0
!"
#
!""
Flat
bottom
P43
,
P44
and
P45
= 0
$&%'
(&)&*
+&,-
.&/0
1324
1&52
1&26
1&25
1&52
1324
6.5. 32-P
OINT LINEARISATION
Programming 32 point linearisation % (0 … 100%) -capacitance can be assigned to the values of level and volume by data pairs. Intermediate
values will be calculated by interpolation. See the example for volume calculation:
1, Select engineering unit (
P00
).
2, Select operating mode (
P01
).
3, Programme required levels (
P05
,
P06
).
5, Assuming lower and upper level being 1 and 5 m respectively first data pair to enter in the
table is: 0% - 1 m, and the last data pair 100% - 5 m.
6, Select your tank shape (
P40
), enter dimensions (
P40
-
P45
).