24/36
♦
TÜV-A 03 ATEX 0019X
♦
cbr2052a0600p_01
P01: - - - a Measurement mode
Parameter value „a” will determine the basic measurement value that will be displayed and proportional with the current output. Depending on the
value of “a” process values as listed in the 3d column can also be displayed by pressing NEXT . For return to the display of the basic value the
ENTER
E
key should be pressed.
a
Measurement mode
Transmitted value
Display
symbol
Displayed values
0
Capacitance %
%
Percentage
1
Level
LEV
Level
2
Level percentage
LEV%
Level percentage, Level
3
Volume
VOL
Volume, Level
4
Volume percentage
VOL%
Volume percentage, Volume, Level
Attention: mind the sequence!
When programming this
parameter the right value “a” will
be blinking first.
Note:
If the change of the level is proportional with the change of the capacitance there will be no difference between relative % (a = 0) and level % (a = 2).
P02: - - b a Engineering units
a
0
Always 0
Attention: mind the sequence!
When programming this
parameter the right value “a” will
be blinking first.
This table is to be understood according to
P00
(c),
P01
(a) and
P02
(c) and irrelevant with measuring percentage (
P01
(a)= 2 or 4 )
Volume
Weight (See also P32)
b
Metric
US
Metric
US
0
m
3
ft
3
tonne
lb (pound)
1
litre
gallon
tonne
tonne