OPERATING THE ENGINE
3-3
Starting the Engine
Starting the Engine at Normal Temperature
1. Confirm that pilot control shut-off lever (1) is in the LOCK
position.
2. Turn engine control dial (3) to the slow idle position.
3. Sound horn to alert bystanders.
4. Insert key switch (2). Turn it to ON position.
5. The basic screen (4) will be displayed on the monitor.
6. Turn key switch (2) to START position to rotate the
starter. The engine will start.
IMPORTANT: Never operate the starter for more than 15
seconds at a time. If engine fails to start, return key
switch to OFF. Wait for more than 30 seconds, then
try again. Failure to do so may cause damage to the
starter and/or discharging the batteries.
This machine adopts the starter energizing time
restriction control. The starter power will be
automatically cut after running 30 seconds.
7. Release key switch (2) immediately after the engine has
started. Key switch (2) will automatically return to ON
position.
f
NOTE: The horn sounds even though key switch (2) is turned
OFF. The engine does not start unless pilot control shut-off
lever (1) is in the LOCK position.
1
2
3
Slow Idle
Fast Idle
4
MADB-03-002
MADB-01-011
MADB-03-001
MADB-01-067
Summary of Contents for Zaxis 33U-5A
Page 4: ......
Page 66: ...SAFETY SIGNS S 54 MEMO ...
Page 104: ...OPERATOR S STATION 1 38 Radio Cab equipped machine Optional 1 Radio Clock 1 MADB 01 005 ...
Page 114: ...BREAK IN 2 2 MEMO ...
Page 160: ...OPERATING THE MACHINE 5 28 MEMO ...
Page 270: ...MAINTENANCE 7 102 MEMO ...
Page 272: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 2 MEMO ...
Page 274: ...STORAGE 10 2 MEMO ...