4-4
4.1.2 Access to the parts on the front side of the equipment
1 Remove the Inner cover (T).
.
2 Remove the fixing screws (2 pieces) and draw the reservoir unit out to the front
halfway by supporting
“a” part (4 places) with both hands.
3 Remove the tubes and cables from the clamp.
4 Pull the reservoir unit out further and put it on the maintenance cover.
Reservoir Unit
Remove
Clamp
Tube/Cable
Tube/Cable
Clamp
[CAUTION]
Carefully mount the Reservoir unit back
to its place so that the piping tube of
the recovery filter is not pinched.
After performing the task of pulling the
Reservoir unit, please make sure that the
level sensor is functioning normally.
Fixing screws
Pull out Reservoir Unit
Reservoir Unit
Inner cover (B)
a
a
【
CAUTION
】
Please do not remove the
lock pin guard.
When it is removed by any
chance, please return it to
the original position.
Lock pin guard
Maintenance cover