4-16
5 Remove the fixing screws (2 positions) of the solenoid valve.
[Caution] Put wiping paper under the solenoid valve to provide for an ink drip.
6 Clean the portion stained with ink and then install the new solenoid valve in reverse order
of the procedures above.
[Caution] Securely set the O-ring in the groove of the solenoid valve.
Pay extra attention not to cause the O-ring to fall off or pinched.
Fixing screws
(2 Positions)
Solenoid valve
O-ring(S24)
O-ring4.7-E227
MV25
(Green)
MV23
(Orange)
MV28
(Gray)
MV8
Gray
MV7
Purple
MV6
Blue
MV5
Green
MV4
Yellow
MV3
Orange
MV2
Red
MV1
Brown