3-11
(3) How to lock the actuator
To lock the actuator, press it downward as shown in the picture below. When you
look the actuator, apply the pressure to the direction of an arrow (to the direction of
inner side of the
connector) to avoid the rotary shaft and the actuator being separated.
[LCD external view
]
[LCD replacement procedures]
(1) Turn off the Main power switch and open the Maintenance door.
(2) Remove Flexible flat cable (FFC) and Touch panel connection cable from EZJ136
board.
(3) Remove Fixing screws 1 (2pieces) and Fixing screws 2 (2pieces), and then remove
EZJ128 board with Board mounting plate.
(4) Remove Backlight harness from LCD.
(5) Remove EZJ136 board with cables connected, from LCD.
(6) Remove Fixing screws 3 (2pieces), and then remove LCD.
(7) Replace LCD with a new one, and then reassemble all the removed parts and cables in
reverse order of the procedures above.
Tighten Fixing screws 2 (2pieces) and Fixing screws 3 (2pieces) with
tightening torque 0.294±0.05Nm. If the tightening torque is too much, LCD will be
broken.
!
Caution
LCD
Maintenance door
Board mounting plate
Flexible flat cable (FFC)
EZJ128 board
Fixing
screws 2
Touch panel
connection cable
Backlight harness
Fixing screws 1
Fixing
screws 3
EZJ136 board
Fixing
screws 3
Summary of Contents for UX Twin Nozzle
Page 1: ...Service Manual HITACHI Printer UX Twin Nozzle Model Revision February 2017 Version A ...
Page 106: ...3 30 Circuit diagram of EZJ127A board ...
Page 123: ...3 47 Circuit diagram of EZJ129 board ...
Page 131: ...3 55 3 3 20 Electrical Connection Diagram ...
Page 151: ...4 17 7 Reset the time of the replaced solenoid to 0 on the Parts usage time management screen ...
Page 352: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram ...
Page 354: ...7 3 7 3 Electrical Connection Diagram Electrical Connection Diagram ...