![Hitachi UX Twin Nozzle Service Manual Download Page 233](http://html.mh-extra.com/html/hitachi/ux-twin-nozzle/ux-twin-nozzle_service-manual_143808233.webp)
5-17
5.10
Thermistor replacement
1
Remove four (4) fixing screws, and then pull out the coupling to the direction of the arrow on the left.
2
Remove the banding band(s) and the packing.
[Caution]
Before removing the banding band and the packing, put a mark on the tube by a tape, etc. as the guide
for reassembling the new ones.
3
Remove the thermistor connector.
4
Take the used thermistor out from the coupling, and then replace it with the new one.
Coupling
Tube (transparent)
Coupling
Fixing screws (2 pieces)
Fixing screws
(2 pieces)
Banding bands (2 locations)
Packing
Put a mark here
New thermistor
Used thermistor
White wire
Red wire