6-35
6.2.21b Pump Motor2 Fault
(*1): When you replace Pump2 motor, refer to “4.8.8 Recovery pump2 motor replacement procedure”.
(*2): When you replace EZJ133 board, refer to
[Replacement procedures of EZJ133 board] in “3.3.1 EZJ133
board (MPU board)”.
[Caution]
Be sure to check that there is no wrong connection of harnesses by referring to
[Connector numbers and
Identifying method of harnesses] in “3.3.20 Electrical Connection Diagram”.
Does the fault recur?
Pump Motor2 Fault
Pull out and insert the connector
・
CN31 of the EZJ133 board
・
CN3 and CN6 of the EZJ138 board
・
pump motor
connector.
Replace the EZJ133 board. *2
Resume the
operation
.
Replace the pump motor2 *1
Does the fault recur?
Yes
No
Yes
No
Does the connection
harness have electrical
continuity?
Replace the connection harness
Does the fault recur?
Yes
No
Yes
No