GS4000 Installation Guide Revision 4.00
520-10-026-30X
4-27
Step 4
Loosen the screws of the cable clamp.
Figure 4.5-15 Loosening the Cable Clamp
Step 5
Put the DC power cable through the cable clamp, and then mount its terminals
with screws in the order of earth (ground) terminal (first), 0V terminal (second) and –48/-60
terminal (third).
Figure 4.5-16 Securing the Terminals
WARNING: WHEN CONNECTING THE DEVICE TO THE DC POWER SUPPLY, USE THE
EARTH (GROUND) TERMINAL TO AVOID AN ELECTRIC SHOCK OR THE
TROUBLE RELATED TO ELECTRIC NOISES.
Screw (M5)
Cable Cramp
0V Terminal
-
48V/-60V Terminal
Ground Terminal
Screw (M6)
DC Power Cable
Cable Clamp
Screw (M6)
Ground Terminal
When using the earth
terminal having two
holes, fix it with two
screws as shown in
the figure on the right.