GS4000 Installation Guide Revision 4.00
520-10-026-30X
4-22
4.5.4 Attachment/Detachment of GS4000-80E2 Power Cables
(1) Attachment of a Cable
WARNING: BECAUSE DC POWER CABLES ARE CONNECTED TO TERMINAL
BOARDS, ATTACHING OR REMOVING A DC POWER CABLE TO OR FROM
THE DEVICE MUST BE DONE BY A TRAINED MAINTENANCE PERSON.
MISHANDLING DC POWER CABLES CAN CAUSE A FIRE OR AN ELECTRIC
SHOCK.
WARNING: MAKE SURE THAT THE CIRCUIT BREAKER OF A POWER FACILITY IS
SET TO OFF BEFORE ATTACHING OR REMOVING A DC POWER CABLE.
ATTACHING OR REMOVING A DC POWER CABLE WITH THE CIRCUIT
BREAKER SET TO ON WILL CAUSE AN ELECTRIC SHOCK.
Step 1
Remove the terminal board cover from the terminal board.
Figure 4.5-4 Removal of the Terminal Board Cover
Step 2
Remove the terminal cover from the terminal board.
Figure 4.5-5 Removal of the Terminal Cover
Terminal Cover
Terminal Board
Power Supply (POW-HSDCE)
Terminal Board Cover
Screw (M2.5)