E3 - 7
(1) Sampling Pulse Adjustment
Incompleted Phenomenon:
The S/N of camera recorded image is poor.
Condition:
Cap the lens (so that no light enters).
Procedure:
1)
Input 1 to PC on the adjustment menu screen.
2)
The screen for checking start of adjustment will appear: Input Y. (*1)
3)
The screen for checking lens cap attachment will appear: Press any key.
4)
Follow the instruction on PC display thereafter.
5)
After the sampling pulse adjustment complete screen appears, press any key to restore the adjustment menu screen.
6)
Turn the video camera/recorder off, leave as is for at least 5 seconds, and then turn it on again. (*1)
*1:
Entering N or [Esc] on the screen for checking start of adjustment will restore the data adjustment menu screen.
*2:
When the video camera/recorder is turned on again, the MAP may not operate normally, and the following
adjustments may not be possible. If this happens, press the [Esc] key to restore the MS-DOS screen, and then
restart the MAP.
(2) Auto Iris Control Adjustment
Incompleted Phenomenon:
The picture becomes too bright.
The picture becomes too dark.
Condition:
Set the zoom to wide end and point at the light box, without chart inserted, to fill the screen.
Procedure:
1)
Input 2 to PC on the adjustment menu screen.
2)
Follow the instruction on PC display thereafter.
3)
After the AIC (auto iris control) adjustment complete screen appears, press any key to restore the adjustment menu
screen.
4)
Turn the video camera/recorder off, leave as is for at least 5 seconds, and then turn it on again. (*1)
*1:
When the video camera/recorder is turned on again, the MAP may not operate normally, and the following
adjustments may not be possible. If this happens, press the [Esc] key to restore the MS-DOS screen, and then
restart the MAP.
***********************************************************
ADJUSTMENT
***********************************************************
[1]
SAMPLING PULSE
[2]
AUTO IRIS CONTROL
[3]
SHUTTER
[4]
WHITE BALANCE
[5]
CHROMA GAIN
[ESC] RETURN TO MAIN MENU
Please select [1] - [5] or [ESC]
Adjustment menu
ADJUSTMENT FINISHED
PRESS ANY KEY
AIC adjustment complete
Checking start of adjustment
PC Display & Figs
NOW GOING TO START SAMPLING PULSE ADJUSTMENT PROGRAM...
ARE YOU SURE? (Y/N)
Please select [Y] - [N] or [ESC]
PLEASE FIT A CAMERA WITH LENS CAP.
ARE YOU SURE?
[PRESS ANY KEY]
CAUTION!
Checking lens cap attachment
PLEASE WAIT AROUND 30 SECONDS...
NOW ADJUSTING...
Smpling pulse adjustment progress
ADJUSTMENT COMPLETED !
[PRESS ANY KEY]
SUCCESS.
Sampling pulse adjustment complete