46
Chapter 3 Installation
|
Hillstone
Hillstone SG-6000 X-Series Hardware Reference Guide
expansion slot. Rotate the levers to outside, and slide the expansion module
straight into the slot along the guide rail.
Figure 3-8: Installing an SCM
6.
When the lever head is inserted into the expansion slot, you should rotate the
levers to the front of the module and slide the SCM into the slot until you feel
resistant.
7.
Tighten the screws on the SCM with a cross screwdriver.
8.
To install more SCMs, repeat Step 3 to 7
Installing an SSM/IOM/QSM/Bypass
The SSM, IOM, QSM or Bypass module of SG-6000-X10800 can be installed in any
slot of slot1 to slot12. You can choose the slot according to needs..
The following takes IOM as an example to introduce how to install an SSM, IOM,
QSM or Bypass module. To install an IOM, take the following steps:
1.
Wear an electrostatic discharge (ESD) strap around your bare wrist and connect
the strap to an ESD point on the chassis. See
2.
Take IOM out from its antistatic bag.