7
Chapter 1 Product Profile
|
Hillstone
Hillstone SG-6000 X-Series Hardware Reference Guide
module)
Red/Always on
The expansion module has failed to boot or has an
error.
Table 1-4: SG-6000-X7180 LED Indicators Description
LED
Color/Status
Description
PWR
Green/Always on
The device power is running normally.
Orange/Always on
The device power is running abnormally.
Red/Always on
Power failure so the system is down.
Off
The device is powered off.
STA
Green/Always on
The system is booting.
Green/Blinking
The system is running normally.
Red/Always on
The system has failed to boot or has an error.
ALM
Red/Always on
The system is sending alarm(s).
Green/Blinking
The system is waiting.
Orange/Blinking
The system is using a trial license.
Orange/Always on
The trial license has expired and there is no
legitimate license installed in the system.
Off
The system is running normally.
HA
Green/Always on
Not using HA, the device is the master device.
Green/Blinking
Two devices are in an HA cluster. This device is
working as the master.
Orange/Blinking
Two devices are in an HA cluster. This device is
working as the salve.
Red/Blinking
HA function has failed.
Off
High Availability is disabled.
SD
Green/Always on
SD card has been inserted and is in normal status.
Green/Blinking
SD card is transmitting data.
Red/Always on
SD card has been inserted but cannot be read or
written.
Off
SD card is not in the slot.
LNK
Green/Always on
The link between this port and its peer device is in
normal status.
Off
The link between this port and its peer device has
failed.
ACT
Orange/Blinking
The port is sending or receiving data.
Off
No data is transmitted on this port.
Front
Slots 1 - 6
Green/Blinking
The expansion module is working normally.
Red/Always on
The expansion module has an error.
Orange/Blinking
The expansion module is starting.
Rear Slots
7 - 10
Green/Blinking
The expansion module is working normally.
Red/Always on
The expansion module has an error.
Orange/Blinking
The expansion module is booting.
SC0
Green/Blinking
SCM in the slot SC0 serves as the master module
and is working normally.