18
Chapter 1 Product Profile
|
Hillstone
Hillstone SG-6000 X-Series Hardware Reference Guide
Power Module
Eight power modules with a power of 1600W can be installed in SG-6000-X10800.
You must install three AC (or four -48V DC) power modules to power the device. If
every slot of device is installed with expansion module, please install at least three AC
(or four -48V DC) power modules.
Four power modules with a power of 650W can be installed in SG-6000-X7180. You
must install two AC (or DC) power modules to power the device. If every slot of
device are installed with expansion module, please install at least 3 AC (or DC) power
modules. You can install a third and fourth power module in the device to offer
redundancy. When four power modules are installed in the device, you are suggested
to connect two of the power modules to a power source and connect the other two to
a different power source. This can ensure that when a power source fails, the other
power modules powered by the different source can begin to work immediately. If you
want to install the SSM-200, QSM-200 or IOM--200 module to the device,
please install at least 3 AC (or DC) power modules.
The power modules are inserted in the power expansion slots of the rear panel.
Notes:
The standby power supply module is hot-swappable.
You are suggested not to use AC and DC power supply modules meanwhile
in one device.
Figure 1-23: SG-6000-X10800 AC Power Module