8
Chapter 1 Product Profile
|
Hillstone
Hillstone SG-6000 X-Series Hardware Reference Guide
Orange/Blinking
SCM in the slot SC0 serves as the backup module
and is working normally.
Red/Always on
SCM in the slot SC0 has an error.
SC1
Green/Blinking
SCM in the slot SC1 serves as the master module
and is working normally.
Orange/Blinking
SCM in the slot SC1 serves as backup module and
is working normally.
Red/Always on
SCM in the slot SC1 has an error.
SYS
(on the
expansion
module)
Green/Always on
The module is booting.
Green/Blinking
The module is working normally.
Red/Always on
The module has failed to start or has a connection
error.
Off
The module is powered off or has been ejected.
LED on
the power
supply
Green/Always on
The power module is working normally.
Green/Blinking
The power module is standby.
Red/Always on
The fan of power module or voltage output has
failed.
Red/Blinking
The power module is using overcurrent protection.
Off
No power input.
LED on
the fan
tray
Green/Always on
The cooling system is working normally.
Red/Always on
One or more fans have failed.
Off
The fan tray is not fully inserted, or it has a circuit
error.
System Parameters
The following table describes the system parameters of SG-6000-X10800 and SG-
6000-X7180.
Table 1-5: SG-6000-X10800/X7180 System Parameters
Item
Description
Fixed Ports
SG-6000-X7180
4 Combo ports (e0/0 is MGT port; others
are HA ports)
2 USB 2.0 Host ports
1 SD card slot
1 Console port (CON port)
1 Auxiliary port (AUX port)
Expansion Modules
SG-6000-X10800
12 general expansion module slots (SSM,
IOM,QSM and Bypass modules can be
inserted)
2 SWM slots
2 SCM slots
SG-6000-X7180
10 general expansion module slots
2 SCM slots