No.
Set the RS-485 No.
Peripheral Type
Select a peripheral from the drop-down list according the actual situation. You can select from
Card Reader, Extension Module, Access Controller, or Disable.
Note
After the peripheral is changed and saved, the device will reboot automatically.
RS-485 Address
Set the RS-485 Address according to your actual needs.
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
Baud Rate
The baud rate when the devices are communicating via the RS-485 protocol.
Set Wiegand Parameters
You can set the Wiegand transmission direction.
Steps
Note
Some device models do not support this function. Refer to the actual products when configuration.
1. Click Configuration → Access Control → Wiegand Settings .
Figure 8-14 Wiegand Page
2. Check Wiegand to enable the Wiegand function.
3. Set a transmission direction.
DS-K5604A-3XF Series Face Recognition Terminal User Manual