CameraLink Area Scan Camera
·
User Manual
66
When the camera’s temperature is higher than the threshold you set, fan starts to work. When
the camera’s temperature is 5 °C (41 °F) lower than the threshold you set, fan stops working.
Only type II camera and type III camera have fan.
9.3 Save and Load User Set
The camera supports 4 sets of parameters, including 1 default set and 3 custom sets. The relation
among 4 sets of parameters is shown below.
Current
Parameter
User
Parameter 1
User
Parameter 2
User
Parameter 3
Device
Default
Parameter
load
save
load
Figure 9-2
Parameter Relation
You can save parameters, load parameters and set user default as shown below.
Save Parameters
Steps:
1.
Click User Set Control, and select a user set in User Set Selector. Here we take selecting User
Set 1 as an example.
2.
Click Execute in User Set Save to save parameters.
Figure 9-3
Save User Set