Exposure Mode
Parameter
Parameter Value Principle
Once
Acquisition Control >
Exposure Auto
Once
Adjust the exposure time
automatically according to
the image brightness. After
adjusting, it will switch to
Off Mode.
Continuous
Acquisition Control >
Exposure Auto
Continuous
Adjust the exposure time
continuously according to
the image brightness.
When the exposure mode is set as Once or Continuous, the exposure time should be within the
range of Auto Exposure Time Lower Limit and Auto Exposure Time Upper Limit, as shown below.
Figure 8-13
Set Exposure Time under Once or Continuous Mode
If the camera is under Continuous exposure mode, once external trigger mode is enabled, the
camera will automatically switch to Off exposure mode.
8.8 Set Gain
8.8.1 Set Analog Gain
The camera supports analog gain function. For specific analog gain range that the camera supports,
please refer to the specifications of the camera.
The camera has 3 types of analog gain: Off, Once and Continuous. The analog gain mode and
principle are shown below.