1.
Click Analog Control and enable Digital Shift Enable.
2.
Enter proper value in Digital Shift.
Figure 8-15
Set Digital Gain
The digital gain is disabled by default, and its range is from -6 dB to 6 dB.
When increasing the digital gain, the image noise will greatly increase too, which will severely
influence image quality. It is recommended to use analog gain first, and then to adjust digital
gain if the analog gain cannot meet demands.
8.9 Set Brightness
The camera brightness refers to the brightness when the camera adjusts image under Once or
Continuous exposure mode, or Once or Continuous gain mode. You can set brightness as shown
below.
You should enable Once or Continuous exposure mode, or Once or Continuous gain mode first
before setting brightness.
Steps:
1.
Click Analog Control > Brightness.
2.
Set Brightness according to actual demand, and its range is from 0 to 255.