CameraLink Area Scan Camera
·
User Manual
36
Chapter 7 I/O Electrical Feature
and Wiring
7.1 I/O Electrical Feature
7.1.1 Line 0 Opto-isolated Input Circuit
The Line 0 opto-isolated input circuit in camera I/O control is shown below.
Line 0+
GPI
Line 0-
VCC
Figure 7-1
Line 0 Internal Circuit
The maximum input current of Line 0 is 25 mA.
Logic 1
Input Level
Logic 0
Input Level
Internal Logic
TDR
TDF
Figure 7-2
Input Logic Level
Table 7-1
Input Electrical Feature
Parameter Name
Parameter Symbol Value
Input Logic Level Low VL
0 VDC to 1 VDC
Input Logic Level High VH
1.5 VDC to 24 VDC