CameraLink Area Scan Camera
·
User Manual
27
Trigger
Sensor
exposure
Burst Count = 4
Figure 5-12
Sequence Diagram of Burst Frame Count
5.4.2 Set Trigger Delay
From camera receiving signal and responding, this period is trigger delay. Its sequence diagram is
shown below.
Sensor
exposure
Exposure 1
Exposure 2
Exposure 3
Trigger_in 1
Trigger
delay
Trigger_in 2
Trigger
delay
Trigger_in 3
Trigger
delay
Figure 5-13
Signal Delay Sequence Diagram
You can set proper value in Trigger Delay, and its range is from 0 μs to 16000000 μs.
Figure 5-14
Set Trigger Delay
5.4.3 Set Trigger Cache Enable
The camera has the function of Trigger Cache Enable. During the triggering process, if the camera
receives new trigger signal, it will save and process the signal if you enable this function. Trigger
cache enable can save up to 2 trigger signals.
You can set Trigger Cache Enable as shown below.