29
Trigger Activation Parameter
Parameter Value
Principle
the trigger signal.
Falling edge
Acquisition Control >
Trigger Activation
Falling Edge
Falling Edge refers to the falling
edge of the trigger signal is
valid, that is camera exposure
and acquisition at the
beginning of the falling edge of
the trigger signal.
You can set trigger activation as shown below.
Steps:
1.
Click Acquisition Control > Trigger Activation.
2.
Select Falling Edge or Rising Edge as Trigger Activation.
Figure 5-16
Set Trigger Activation
5.4.5 Set Trigger Debouncer
The external trigger input signal of the camera may have signal bounce that may cause false trigger.
Thus, it is necessary to debounce the external trigger signal, and its sequence diagram is shown
below.