Type IV camera and type V camera do not have bi-direction I/O function.
Line 2 Configured as Input
With the condition of 100 Ω and 5 VDC, the logic level and electrical feature of configuring Line 2
as output are shown below.
Logic 1
Input Level
Logic 0
Input Level
Internal Logic
TDR
TDF
Figure 7-6
Input Logic Level
Table 7-4
Electrical Feature of Line 2 Input
Parameter Name
Parameter Symbol
Value
Input Logic Level Low
VL
0 VDC to 0.5 VDC
Input Logic Level High
VH
1.5 VDC to 24 VDC
Input Rising Time
TDR
< 1 μs
Input Falling Time
TDF
< 1 μs
Make sure the input voltage is not from 0.5 VDC to 1.5 VDC as the electric status between
these two values are not stable.
The breakdown voltage is 30 VDC, and keep voltage stable.
To prevent damage to the GPIO pin, please connect GND first and then input voltage in Line 2.
Line 2 Configured as Output
When the environment temperature is 25 °C (77 °F), the relation among external voltage,
resistance and the output level low is shown below.