CameraLink Area Scan Camera
·
User Manual
26
5.4 Trigger Related Parameters
Under external trigger mode, you can set burst frame count, trigger delay, trigger cache enable,
trigger activation and trigger debouncer. Different trigger sources can set various trigger
parameters, and their relation is shown below.
Table 5-4
Trigger Source and Trigger Parameter
Trigger Source
Trigger Parameter
Software
Trigger
Hardware
Trigger
Counter
Trigger
Frame
Grabber
Trigger
Burst frame count
Support
Support
Support
Support
Trigger delay
Support
Support
Support
Support
trigger cache enable
Support
Support
Support
Support
Trigger activation
Not support
Support
Support
Support
Trigger debouncer
Not support
Support
Not support Support
5.4.1 Set Burst Frame Count
Under external trigger mode, you can set burst frame count as shown below.
Steps:
1.
Click Acquisition Control > Acquisition Burst Frame Count.
2.
Enter proper value according to actual demands. Its range is from 1 to 1023.
Figure 5-11
Set Burst Frame Count
When Acquisition Burst Frame Count is 1, it is in single frame trigger mode. When Acquisition
Burst Frame Count is larger than 1, it is in multi-frame trigger mode. If Acquisition Burst Frame
Count is n and when inputting 1 trigger signal, the camera stops acquiring images after exposing n
times and outputs n frame images. The sequence diagram of burst frame count is shown below.