CameraLink Area Scan Camera
·
User Manual
32
The Line Inverter parameter is disabled by default.
6.2.2 Enable Strobe Signal
The strobe signal is used to directly output I/O signal to external devices when camera’s event
source occurs. You can enable strobe signal as shown below.
The camera currently supports setting ExposureActive as line source only.
Steps:
1.
Click Digital IO Control.
2.
Set ExposureActive as Line Source.
3.
Enable Strobe Enable.
Figure 6-3
Enable Strobe
Regarding strobe signal, you can also set its duration, delay and pre-delay.
Set Strobe Line Duration
You can set strobe line duration as shown below.
Steps:
1.
Click Digital IO Control > Strobe Line Duration.
2.
Enter proper value in Strobe Line Duration, and its range is from 1 μs to 1000000 μs.