Installation & Adjustments
Synergy 0.5 Turntable Stretch Wrapper Operation Manual
Highlight Industries, Inc. ● 2694 Prairie SW, Wyoming, Mi 49519 ● 1-800-531-2465
29
Highlight Recommended Configuration Values
Note
Changing the scale parameters to values other than the Highlight
recommended values may result in poor scale operation.
Name/Code
Description
Highlight
Suggested
Value
F1:
Graduations
Specifies the number of full-scale graduations. Value
should be consistent with legal requirements and
environmental limits on the useful system resolution.
5000
F2: Span Gain Span Gain is related to A/D integration time. The larger
the span gain, the higher the internal resolution, but the
slower the update speed. Note that the scale must be re-
calibrated whenever this parameter is altered. See
Appendix C in the scales manual for more information.
100
F3: Zero Track
Band
Selects the range within which the scale will
automatically zero. Note that the scale must be in a
standstill to zero the scale.
3
F4: Zero
Range
Selects the range within which the scale may be zeroed.
Note that the indicator must be in standstill to zero the
scale.
100
F5: Motion
Band
Sets the level at which motion is detected by comparing
the present display update with the previous one. If
motion is not detected for two seconds or more, scale is
in standstill and can process a Print or Zero command.
Maximum value varies depending on local regulations
1
F6: Digital
Filter
Averages weight readings to produce higher stability but
the slower the indicator’s response time. Choose 8
unless a very fast response is needed.
8
F7:Overload
Limit
Selects the desired formula which determines the point
at which the indicator shows overload. All selections are
based on the primary unit selected in F8.
2%
F8: Calibration
Unit
Selects the primary base unit to be used in the
calibration process. Also the default unit for normal
operation. 1 = pounds, 2 = kilograms.
1
F9: Display
Divisions
Determines the desired weight increments. Value should
be consistent with legal requirements.
1
F10: Decimal
Point
Determines the location of the decimal point.
0
F16:Zero
Calibration
Places the scale in a Zero Calibration routine. See
below.
See below.
F17:
Span
Calibration
Places the scale in a Span Calibration routine. See
below.
See below.