![Highlight Synergy 0.5 Operation Manual Download Page 20](http://html1.mh-extra.com/html/highlight/synergy-0-5/synergy-0-5_operation-manual_2130600020.webp)
Installation & Adjustments
Synergy 0.5 Turntable Stretch Wrapper Operation Manual
Highlight Industries, Inc. ● 2694 Prairie SW, Wyoming, Mi 49519 ● 1-800-531-2465
19
drC Menu
Code Sub-
Code
Name/Description
Adjustment
Range
Factory
Setting
bFr
Standard Motor Frequency
50/60
50 Hz
nPr
Rated Motor Power (% of drive rated HP)
0.5-1.2
1
UnS
Rated Motor Voltage
100-480V
230V
nCr
Rated Motor Current
plate
Varies
FrS
Rated Motor Frequency
10-400Hz
50 Hz
nSP
Rated Motor Speed
0-24000rpM
Varies
tFr
Maximum Frequency
10-400Hz
72 Hz
Ctt
Motor Control Type:
PErF
– Performance, Sensorless Vector
Std
– Standard, Volts/Hertz
PUNP
– Pump, low torque
Std
UFr
IR Compensation:
Optimizes torque at very low speeds
25-200%
100%
SLP
Slip Compensation
0-150%
100%
StA
Frequency Loop Stability:
Adjusts overshoots and oscillations at the end
of acceleration or deceleration. A higher
number decreases oscillations
0-100%
20%
FLG
Frequency Loop Gain:
Adjusts the slope of the speed increase. A
lower number decreases oscillations.
0-100%
20%
tUn
Motor Auto Tuning:
Automatically tunes the drive to the motor
profile
nO/YES/dOnE nO