Installation & Adjustments
Synergy 0.5 Turntable Stretch Wrapper Operation Manual
Highlight Industries, Inc. ● 2694 Prairie SW, Wyoming, Mi 49519 ● 1-800-531-2465
28
The optional scale package allows the user to quickly measure the weight of a package
placed on the machine. To operate correctly and efficiently the scale needs to be
configured with the correct settings. Below are instructions on how to re-configure the scale
and the settings that have been pre-programmed. Re-configuring the scale is not required
unless there is a problem with the existing scale or a new scale is added to the machine.
Refer to the scale manual for more information.
Note
Changing the scale parameters to values other than the Highlight
recommended values may result in poor scale operation.
Navigating the Scale Menu
Step 1: Turn the scale display over so you are looking from above down at the back side of
the scale and turn off the scale power.
Step 2: Remove the two small screws holding a small plate on the back of the scale.
Step 3: Looking down at the scale, move the switch under the plate to the right.
Step 4: Turn the scale power back on.
Step 5: Press the “PRINT / >>” button until the desired setting appears on the screen.
Step 6: Press th
e “ZERO” button to enter the parameter set-up.
Step 7: Press the “PRINT / >>” button until the display reads the correct setting and press
the “SET / NET” button.
Step 8: Turn the power back off, move the switch under the plate to the left, and turn the
power back on.
Step 9: Replace the screws on the back cover and retighten the scale swivel grips on the
side.
Step 10: The scale is now ready to use.