![Highlight Synergy 0.5 Operation Manual Download Page 24](http://html1.mh-extra.com/html/highlight/synergy-0-5/synergy-0-5_operation-manual_2130600024.webp)
Installation & Adjustments
Synergy 0.5 Turntable Stretch Wrapper Operation Manual
Highlight Industries, Inc. ● 2694 Prairie SW, Wyoming, Mi 49519 ● 1-800-531-2465
23
OCF
Motor short circuit
Short-circuit or grounding at the
drive output
Ground fault during running
status
Commutation of motors during
running status
Significant current leakage to
ground if several motors are in
parallel
Check the cables connecting
the drive to the motor, and the
motor insulation
Connect motor chokes
SCF1
Ground short circuit
SCF4
IGBT short circuit
Internal power component short
circuit detected at power on
Contact your local Schneider
Electric representative
SOF
Over-speed
Instability or over-speed associated
with the inertia of the application
Check the motor
Over-speed is 10% more than
the maximum frequency (tFr).
Adjust this parameter if
necessary
Add a braking resistor
Check the size of the
motor/drive/load
Check the parameters of the
speed loop (gain and stability)
tnF
Auto-Tuning
Motor not connected to the drive
One motor phase loss
Special motor
Motor is rotating
Check that the motor/drive are
compatible
Check that the motor is present
during auto-tuning
If an output contactor is being
used, close it during auto-tuning
Check that the motor is
completely stopped
LFFI
AI current lost fault
Detection if:
Analog input AI1 is configured as
current
AI1 current scaling parameter of
0% is greater than 3mA
Analog input current is lower
than 2mA
Check the terminal connections
ObF
Over-braking
Braking too sudden or driving load
Increase the deceleration time
Install a module unit with a
braking resistor if necessary
Check the line supply voltage to
be sure it is under the maximum
OHF
Drive overheat
Drive temperature too high
Check the motor load, the drive
ventilation, and the ambient
temperature. Wait for the drive to
cool down before restarting.
OLC
Process overload
Process overload
Check the process and the
parameters of the drive to be in
phase
OLF
Motor overload
Triggered by excessive motor
current
Check the setting of the motor
thermal protection, check the
motor load