Installation & Adjustments
Synergy 0.5 Turntable Stretch Wrapper Operation Manual
Highlight Industries, Inc. ● 2694 Prairie SW, Wyoming, Mi 49519 ● 1-800-531-2465
21
L2H
– Input L2 active high
L3H
– Input L3 active high
L4H
– Input L4 active high
AdC-
AdC
Automatic DC Injection:
nO
– function inactive
YES
– Time limited DC injection
Ct
– Continuous DC injection
YES
SdC1
Automatic DC Injection Current
0-120% if nCr 70%
tdC1
Automatic DC Injection Time (seconds)
0.1-30 s
0.5 s
PSS-
PS2
Second Preset Speed Assignment:
nO
– Function inactive
L1H
– Input L1 active high
L2H
– Input L2 active high
L3H
– Input L3 active high
L4H
– Input L4 active high
nO
SP2
Second Preset Speed Reference
0-400 Hz
10 Hz
CLI-
CL1
Current Limitation
0.25-1.5 plate varies
SPL-
LSP
Low Speed Setting (Hz)
0-HSP
0 Hz
HSP
High Speed Setting (Hz)
LSP-tFr
60 Hz
FLt Menu
Code Sub-
Code
Name/Description
Factory
Setting
rSF
Fault Reset Assignment:
nO
– Function inactive
L1H
– Input L1 active high
L2H
– Input L2 active high
L3H
– Input L3 active high
L4H
– Input L4 active high
nO
Atr-
Atr
Automatic Restart:
nO
– Function inactive
YES
– Automatic drive restart after fault condition
nO
tAr
Max automatic restart time
5 min
FLr
Flying Restart (Catch on the fly):
Restarts the motor at the estimated speed the motor is already
going.
nO
– Function inactive
YES
– Function active
nO
tHt-
ItH
Motor Thermal Current
varies