![Highlight Synergy 0.5 Operation Manual Download Page 21](http://html1.mh-extra.com/html/highlight/synergy-0-5/synergy-0-5_operation-manual_2130600021.webp)
Installation & Adjustments
Synergy 0.5 Turntable Stretch Wrapper Operation Manual
Highlight Industries, Inc. ● 2694 Prairie SW, Wyoming, Mi 49519 ● 1-800-531-2465
20
CtL Menu
Code Sub-
Code
Name/Description
Factory
Setting
Fr1
Speed Reference Channel 1:
AI1
– Terminal analog input
LCC
– Remote Display
Ndb
– Modbus
AIU1
– Jog dial (wheel) on drive
AI1
CHCF
Channel Configuration:
SIN
– Not separate mode. Speed and run commands from the
same source.
SEP
– Separate mode. Speed and run commands from
different sources.
SIM
Cd1
Command Channel 1 (run fwd/rev, stop):
Only appears if CHCF is set to SEP.
tEr
– terminals
LOC
– Local
LCC
– Remote display
Ndb
– Modbus
tEr
FUn Menu
Code Sub-
Code
Name/Description
Adjustment
Range
Factory
Setting
rPt-
ACC
Acceleration Time (seconds)
0.0-999.9 s
3.0 s
dEC
Deceleration Time (seconds)
0.0-999.9 s
3.0 s
brA
Decel Ramp Adaptation Assignment:
nO
– Function inactive. (Used with dynamic
braking)
YES
–
Automatically
increases
the
deceleration time to prevent a DC bus
overvoltage
dYnA
– Most rapid deceleration possible
without a dynamic braking resistor.
YES
Stt-
Stt
Type of Stop:
rNP
– Ramp Stop
FSt
– Fast Stop
nSt - Freewheel
rNP
rrS
Reverse Direction Assignment:
nO
– Function inactive
L1H
– Input L1 active high
nO