![Herz firestar de Luxe 18 Operating Instructions Manual Download Page 69](http://html.mh-extra.com/html/herz/firestar-de-luxe-18/firestar-de-luxe-18_operating-instructions-manual_2127131069.webp)
Fault reports and their corrections
10
69
No. Fault report
Cause of fault
Fault correction
191
Ready
Boiler temperature above boiler max
(90 °C)
boiler loaded with to much wood
(incorrect operation); Back flow
pump or back flow mixer defect
too small buffer tank
too small buffer tank
▪
Put in less wood
▪
Renew return flow pump or return
flow mixer
▪
increase buffer volume
192
Heating up
At lighting up the boiler has not
reached the flue temperature
threshold in the prescribed time
Too coarse material used; Too moist
wood used;
burner plate holes blocked
▪
Use small wood
▪
Use dry log wood
▪
Clean burner plate holes
193
Re-heating
At re-heating the boiler has not
reached
the
flue
temperature
threshold in the prescribed time
Too coarse material used;
Too moist wood used;
burner plate holes blocked
▪
Use small wood
▪
Use dry log wood
▪
Clean burner plate holes
194
EEPROM
Error at writing / reading at EEProm
▪
Replace control
▪
✆
- contracting party
195
STACK HZS621/622
Overflow from the stack pointer
▪
Replace control
▪
✆
- contracting party
196
STACK HZS631
Overflow from the stack pointer
▪
Replace control
▪
✆
- contracting party
197
CAN HZS621/622
if CAN communication to the power
unit is interrupted
▪
Replace control
▪
✆
- contracting party
198
CAN HZS631
if CAN communication to the power
unit is interrupted
▪
Replace control
▪
✆
- contracting party
199
CPU Update
Software-Update are carried out
▪
Reboot of the Control
249
AUTOREBOOT 2
Control restarted due to overload
(e.g. network overload)
▪
Reboot of the Control
▪
adjust Network configuration
250
AUTOREBOOT 24
Software-monitoring fault
✆
- contracting party
251
AUTOREBOOT 50
Software-monitoring fault (problems
with USB-stick)
•
FORMAT USB-STICK via T-Control
-> if it does not work, the USB stick
is defective
✆
- contracting party
252
AUTOREBOOT 51
Software-monitoring fault
✆
- contracting party
253
AUTOREBOOT 67
Software-monitoring fault
✆
- contracting party
254
AUTOREBOOT 68
Software-monitoring fault
✆
- contracting party
Summary of Contents for firestar de Luxe 18
Page 1: ...OPERATING INSTRUCTIONS Log wood boiler firestar de Luxe 18 40 ...
Page 80: ...16 Annex 80 16 ANNEX 16 1 Additional boiler module Hydraulic recommendation 1 ...
Page 81: ...Annex 16 81 Hydraulic recommendation 2 ...
Page 82: ...16 Annex 82 16 2 Solar module Program 1 ...
Page 83: ...Annex 16 83 Program 2 ...
Page 84: ...16 Annex 84 Program 3 ...
Page 85: ...Annex 16 85 Program 4 ...
Page 86: ...16 Annex 86 Program 5 ...
Page 87: ...Annex 16 87 Program 6 ...
Page 88: ...17 Notes 88 17 NOTES ...
Page 89: ...Notes 17 89 ...