Boiler control
9
57
The T-Control is connected to the repeater or router via Ethernet (LAN). The repeater or router must be
configured so that it communicates with the Internet router via WLAN.
After setting up the repeater or router, the network settings must be made in the T-Control.
9.14.2
Modbus
– settings
Navigation:
Screen:
By pressing the button:
active
Modbus TCP activated (green) or deactivated (black).
Port
Setting up the TCP port number. 502 is reserved for Modbus-TCP.
Timeout
Setting up the time delay of the data transfer
RX / TX Buffer
Setting up the buffer size in byte
max. values
Setting up the maximum values of the servers.
Accept
Changes
Save changes
the network configuration page will be displayed again.
Note:
Modbus is an application protocol to exchange messages between intelligent Modbus controllers in the
building management system. The Modbus protocol “TCP” is used in the HERZ control. This protocol
transmits the encoded data via LAN cable. Modbus ensures that connected controllers in the building
management system receive the transmitted data from the boiler, so they can continue processing.
Summary of Contents for firestar de Luxe 18
Page 1: ...OPERATING INSTRUCTIONS Log wood boiler firestar de Luxe 18 40 ...
Page 80: ...16 Annex 80 16 ANNEX 16 1 Additional boiler module Hydraulic recommendation 1 ...
Page 81: ...Annex 16 81 Hydraulic recommendation 2 ...
Page 82: ...16 Annex 82 16 2 Solar module Program 1 ...
Page 83: ...Annex 16 83 Program 2 ...
Page 84: ...16 Annex 84 Program 3 ...
Page 85: ...Annex 16 85 Program 4 ...
Page 86: ...16 Annex 86 Program 5 ...
Page 87: ...Annex 16 87 Program 6 ...
Page 88: ...17 Notes 88 17 NOTES ...
Page 89: ...Notes 17 89 ...