![Hella APS-R Installation And Configuration Manual Download Page 52](http://html1.mh-extra.com/html/hella/aps-r/aps-r_installation-and-configuration-manual_2121286052.webp)
9
Appendix
9.1 Detection area
Maximum detection area depending on installation height
cm
Metric system
Inch
Feet
Instal.
Height
Width
Depth
Instal.
Height
Width
Depth
Instal.
Height
Width
Depth
190
167
140
74.8
65.7
55.1
6.23
5.48
4,59
200
191
160
78.7
75.2
63.0
6.56
6.26
5.25
210
215
180
82.7
84.6
70.9
6.89
7.05
5.90
220
238
200
86.6
93.7
78.7
7.22
7.81
6.56
230
262
220
90.6
103.1
86.6
7.54
8.59
7.22
240
286
240
94.5
112.6
94.5
7.87
9.38
7.87
250
310
260
98.4
122.0
102.4
8.20
10.17
8.53
260
334
280
102.4
131.5
110.2
8.53
10.96
9.18
280
381
320
110.2
150.0
126.0
9.18
12.5
10.5
300
429
360
118.1
168.9
141.7
9.84
14.07
11.81
320
477
400
126.0
187.8
157.5
10.50
15.65
13,12
340
524
440
133.9
206.3
173.2
11.15
17.19
14.43
360
572
480
141.7
225.2
189.0
11.81
18.76
15.74
380
620
520
149.6
244.1
204.7
12.46
20.34
17.06
400
667
560
157.5
262.6
220.5
13.12
21.88
18.37
9.2 Ordering Information
Product
Description
Order no.
Old order no.
APS-R
Advanced People Sensor
with local DC power supply
for ceiling heights from 2.0 m -
4.00 m
013.928-007
510239
APS-R-PoE
Advanced People Sensor
with Power over Ethernet
for ceiling heights from 2.0 m -
4.00 m
013.929-007
510238
Product
Appendix
Ordering Information
52
09.06.2017
The reproduction, distribution and utilization of this document as well as the communication of its contents to others
without express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
Summary of Contents for APS-R
Page 64: ......