The device will be positioned above the area to be monitored. The
installation height shall be between 200 cm and 400 cm above the
floor. The absolute minimum is 190 cm.
Height
Area covered
200 cm
191 x 160 cm
250 cm
310 x 260 cm
300 cm
429 x 360 cm
400 cm
667 x 560 cm
The device is very flexible with regard to the mounting position. To
a certain degree, it can be rotated around all axes, and positioned
off the center.
For optimum performance, it is of great importance to ensure a
good sight of the head/shoulder region of all persons in the field of
view. The center point of the region to be monitored should be
roughly in the center of the camera image.
Small obstacles like hand rails and door hinges can be tolerated
but should be avoided in order to simplify the initial setup.
Installation heights, areas covered
Structure and function
Hardware
09.06.2017
13
The reproduction, distribution and utilization of this document as well as the communication of its contents to others
without express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.