Code jumpers allow the option of using preconfigured devices for
multiple different installation sites. Multiple specific parameter sets
(for instance with different IP addresses for each door of a vehicle)
can be stored on the device. The parameter set to be used will
then be selected with the jumpers. The four jumpers enable 16 dif-
ferent combinations.
–
The code jumper ports are NOT suitable as regular
inputs for external process signals.
–
The length of the jumper wires must not exceed
10 cm.
Jumpers
DID4
(No. 4)
DID3
(No. 3)
DID2
(No. 2)
DID1
(No. 1)
Code
number
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
(DID =
D
oor
ID
entification)
Code Jumper
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
1
2
3
4
Fig. 3: Code jumper for APS-R
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
1
2
3
4
Fig. 4: Code jumper for APS-R-PoE
Structure and function
Hardware
09.06.2017
11