![Hella APS-R Installation And Configuration Manual Download Page 36](http://html1.mh-extra.com/html/hella/aps-r/aps-r_installation-and-configuration-manual_2121286036.webp)
n
Click the
“Auto adjust”
button ( Fig. 36/2) to apply these new
measured values to all of the polygon points.
n
A single polygon point height value can be changed by
selecting it in the live view and either:
–
updating the input field with the measured value using the
“greater than”
button.
–
Manually typing a value into the input field ( Fig. 36/4).
–
Manually increasing/decreasing the value in the input field
using the spin control.
Ceiling panels, door compartments, exit signs or hanging objects
that intrude into the monitored area of the device from the top can
affect the counting accuracy. If People can stand below these
objects, they must be masked to disregard them in count calcula-
tions.
Activate the
“Edit”
button ( Fig. 38/1) to mark obstructed objects in
the live view.
Obstructions
Range
Floor Area
Obstructions
Range
Floor Area
1
2
3
Fig. 39: Live view with partial marked obstructed object
n
Click the
“Obstructions”
button ( Fig. 39/1) to see marked
objects.
n
Click
“Pencil”
or
“Eraser”
button ( Fig. 38/3) to draw or erase
marks in the live view.
n
Click
“10 Px”
or
“20 Px”
button ( Fig. 38/2) to define the line
width for drawing/erasing.
n
Click and hold mouse button in the live view to draw lines
( Fig. 39/3) for marking objects ( Fig. 39/2) .
n
Click the
“Save”
button ( Fig. 38/5) to save all the settings in
the device.
Obstructions
1
2
3
4
5
6
Fig. 38: Obstructions
Configuration
Camera Position
36
09.06.2017
The reproduction, distribution and utilization of this document as well as the communication of its contents to others
without express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
Summary of Contents for APS-R