Restricted air flow into
Blower(s) air inlet.
Clean Blowers.
Refer to
“steps to Maintain your
Blower and Flipper assembly.”
Too much heat draw on
Heatmor Furnace.
Verify HEATMOR™
furnace size for
application.
Contact your
Local Dealer
.
Water Level low.
Add Water.
Refer to
“Filling the heatMOr™
Outdoor Furnace initially with
Water.”
Excessive moisture in
Fuel.
Use dryer wood pellets.
Refer to
“What can i Burn”
Furnace has
excessive
moisture in
Firebox.
Chimney plugged.
Clean Chimney.
Refer to
“chimney stub / chimney
extension(s).”
Flue plugged.
Clean Flue.
Refer to
“Flue.”
Ashes in Air Box(s).
Clean Air Box(s).
Refer to
“air Box.”
Too many ashes in
Furnace.
Clean out ashes.
Refer to
“ash Management and
removal.”
Water temperature not
being held in the 165-185
degree Fahrenheit range.
Contact your
Local Dealer
.
Excessive Moisture in
Fuel
Use dryer wood pellets
Refer to
“What can i Burn”
PrOBLeM
cause
sOLutiOn
PrOceDure