68
smoke from
chimney is an
annoyance.
Chimney is not
high enough.
Add Chimney
Extension.
Refer to
“chimney extension(s).”
Improper location of
furnace (trees, buildings,
winds, neighbors).
Possibly relocate
furnace. Contact local
dealer.
Contact your
Local Dealer.
Draft blower has just
turned off.
Smoke will dissipate.
Burning garbage.
DO NOT BURN
GARBAGE.
Contact your
Local Dealer.
Wood pellets are too wet.
Burn wood pellets with
right moisture content
Refer to
“What can i Burn”
Burning what
seems to be a lot
of wood pellets.
Losing heat into the
ground. Poor insulation.
Re-insulate water lines
and maintain a dry
perimeter.
Contact Your
Local Dealer.
Ground water is
extracting heat from the
water lines.
Provide a method for
ground water to drain.
Contact Your
Local Dealer.
Pellets are unburnt in
the ashpan, auger speed
control too fast
Turn down the auger
speed control
Refer to
“Loading Wood Pellets into
the heatmor
tM
”
Wood pellets have a lot
of ash or low heating
value.
Change type of wood
pellets.
Refer to
“What can i Burn”
Top flue is clogged.
Clean Top Flue.
Refer to
“Flue.”
Using more heat in
building than you realize
(heating more sq.ft.,
appliances, with one heat
source than before).
Consult Dealer.
Verify furnace size for
complete applications.
Contact Your
Local Dealer.
Refer to
“installation Manual.”
PrOBLeM
cause
sOLutiOn
PrOceDure