51
Ignition Switch
Principles
1) To provide means of relighting the fire electronically.
2) To provide a means of turning off ignitor on demand.
3) To provide a visual warning that electrical power to the ignitor
has been terminated.
Operation of the Ignitor Switch
• By adjusting the ignitor switch to the up position, electrical power is
supplied to the ignitor.
• By adjusting the ignitor switch to the down position, the electrical
power to the ignitor is manually terminated.
• Refer to “Lighting the HEATMOR™ for the First Time “.
Removal and Replacement of the Ignitor
1) Remove the airbox cleanout cover and pull out the ignitor.
2) Remove the fan so that the fan hole opening is accesible. Replace the ignitor through this hole.
3) Replace the fan and rewire the new ignitor though the airbox clean out cover. Replace the airbox
cleanout cover.
Removal and Replacement of the Fan Power/Light Switch
1) Turn off the main electrical power supply to the
HEATMOR™.
2) Remove the switch cover plate.
3) Make a sketch of the location of the wires on the switch.
4) Remove the wires, and replace the switch. This is a
special 3-way switch.
5) Replace the wires as in the diagram.
6) Secure the cover plate.
7) Turn the main electrical power supply back on to the
HEATMOR™.
note: it is recommended to contact a licensed electrician to perform the above operation.
In the Event of a Power Failure
If a power failure occurs during the use of a HEATMOR™, do not open the firebox door to provide draft for
the fire to burn. Allow the fire to go out. In case of a prolonged power failure, a generator should be used as a
back-up power source.
Ignitor Switch (right switch)
Ignitor
Summary of Contents for 200 SSP
Page 1: ...Outdoor Furnaces TM save these instructions...
Page 8: ...3 EPA PHASE 2 HANGTAG MODEL 200 SSP...
Page 9: ...4...
Page 10: ...5 HEATMOR Stainless Steel PELLET BURNER Outdoor Furnace Model Chapter 1 Model 200 SSP...
Page 77: ...72 Outdoor Furnaces...
Page 79: ...74...