47
Electronic Controller Temperature Probe
Principles
The temperature probe is how the Electronic Controller reads the temperature of the water in the water jacket.
Removal and Replacement
1) Turn off the main power supply to the HEATMOR™.
2) Remove the 6 screws from the inside front panel that hold the Electronics.
3) Pull the panel away from the housing to obtain clearance to disconnect the temperature probe
from the electronic controller.
4) Pull the temperature probe out of the well and disconnect from the
electronic controller.
5) Install the new temperature probe wires into the electronic controller
and install the probe into the well.
6) Replace the Electronics panel.
Watlow Flame Sensor Control
Principles
The Watlow Flame Sensor Control is a safety feature to prevent adding fuel to the firepot when it is not wanted.
1) Below its
temperature
setting it will not allow the auger to feed pellets into the firepot.
Operation
The factory setting on this flame sensor is 200
o
F. For ignition, you should turn this setting down for only a short
time period to allow ignition then return its setting to 200
o
F for safety. See “Lighting the HEATMOR™ for the
First Time”.
Removal and Replacement
1) Turn off the main power supply to the HEATMOR™.
2) Remove the 6 screws from the inside front panel that hold
the Electronics.
3) Pull the panel away from the housing to obtain clearance to
work on the Watlow Flame Sensor Control from the back.
4) Disconnect and label or draw a diagram of each wire
connection on the Watlow Flame Sensor.
5) Replace the Flame Sensor and reverse the steps above
for re-installation.
Electronic Controller
Temperature Probe
Watlow Flame Sensor Control