iF the Water teMPerature is hiGh enOuGh tO triGGer
the hiGh Water teMPerature saFetY shutOFF,
the FrOnt LiGht WiLL nOt turn On When the
Fan POWer sWitch is in the DOWn POsitiOn.
Front Light and Fan Power Switch
Principles
1) To provide light while fueling.
2) To provide a means of turning off the combustion air blower on
demand.
3) To provide a visual warning that electrical power to the combustion
air blower has been terminated.
Operation of the Front Light and Fan Power Switch
• By adjusting the fan power switch to the down position, the electrical
power to the combustion air blower is manually terminated,
and the front light turns on.
• This light will then illuminate the area in front of the HEATMOR™.
• The light must be turned off for electrical power to be running to the combustion air blower.
Removal and Replacement of the Front Light Bulb
1) Remove the glass globe by first loosening the setscrew and then unscrew the globe.
2) Replace the light bulb.
3) Replace the globe and tighten the setscrew.
Removal and Replacement of the Fan Power/Light Switch
1) Turn off the main electrical power supply to the HEATMOR™.
2) Remove the switch cover plate.
3) Make a sketch of the location of the wires on the switch.
4) Remove the wires, and replace the switch. This is a special 3-way switch.
5) Replace the wires as in the diagram.
6) Secure the cover plate.
7) Turn the main electrical power supply back on to the HEATMOR™.
note: it is recommended to contact a licensed electrician to perform the above operation.
Front Light
Front Light and Fan Power Switch
(left switch)
Summary of Contents for 200 SSP
Page 1: ...Outdoor Furnaces TM save these instructions...
Page 8: ...3 EPA PHASE 2 HANGTAG MODEL 200 SSP...
Page 9: ...4...
Page 10: ...5 HEATMOR Stainless Steel PELLET BURNER Outdoor Furnace Model Chapter 1 Model 200 SSP...
Page 77: ...72 Outdoor Furnaces...
Page 79: ...74...