MULTI POSITION

INSTALLER / SERVICE TECHNICIAN:

USE THE INFORMATION IN THIS MANUAL FOR THE  INSTALLATION  AND 
SERVICING  OF  THE  FURNACE  AND  KEEP  THE  DOCUMENT  NEAR  THE 
UNIT FOR FUTURE REFERENCE.

HOMEOWNER:

PLEASE  KEEP  THIS  MANUAL  NEAR  THE  FURNACE  FOR  FUTURE 
REFERENCE.

(3 WIRES 120/240 – 60 – 1)

Summary of Contents for SUPREME FEM10-M2401AM-A

Page 1: ...ebec Canada J1L 1V8 Caution Do not tamper with the unit or its controls Call a qualified service technician Printed in Canada Printed on 100 recycled paper DNS 0981 Rev A MULTI POSITION INSTALLER SERV...

Page 2: ...ON 8 5 INFORMATION 9 TABLES AND FIGURES FIGURE 1 CONFIGURATION UPFLOW INSTALLATION 4 FIGURE 2 CONFIGURATION DOWNFLOW INSTALLATION 4 FIGURE 3 CONFIGURATION HORIZONTAL INSTALLATION 4 FIGURE 4 MANUAL FUR...

Page 3: ...ualified persons can result in hazards to them and to others Installations must conform to local codes or in the absence of same to codes of the country having jurisdiction The information contained i...

Page 4: ...uding 20 k W can be installed with a zero clearance to combustible material Ducts for furnaces of 23 kW or more must have a clearance of 25 mm 1 to combustible material for the first 0 9 m 36 of duct...

Page 5: ...ontrol the temperature of the area to be heated Follow the instructions supplied with the thermostat Install the thermostat on an interior wall in a location where it will not be subject to direct sun...

Page 6: ...airflow refer to the following table as well as the airflow tables based on static pressure in the Technical Specifications section of this manual For the adjustment of the airflow on heating mode to...

Page 7: ...t of the room is in the heating mode and is set higher than the ambient temperature To start the unit turn the main electrical switch on 3 2 OPERATING SEQUENCE Heating mode 1 The thermostat closes the...

Page 8: ...pply air plenum just outside the range of radiant heat from the heat exchanger 0 3 m 12 from the plenum of the main take off is usually sufficient 4 1 AIR FILTER The filter supplied with the unit is t...

Page 9: ...ame and address START UP RESULTS Voltage Total current consumed by the elements Supply air temperature Return air temperature Supply air duct static pressure Return air duct static pressure Total pres...

Page 10: ...84 100 112 125 119 134 155 Maximum size circuit breaker Amp 2 60 90 100 125 125 125 150 175 BLOWER DATA factory adjusted to a static pressure of 0 5 W C Blower speed at 0 50 W C static pressure LOW M...

Page 11: ...5 CFM more or less These readings were taken with the air filter installed TABLE 3 Air Flow CFM SUPREME with 1 HP motor 0 1 0 2 0 3 0 4 0 5 0 6 0 7 LOW 1035 1030 1030 1025 1020 1020 1015 MED LOW 1315...

Page 12: ...12 FIGURE 6 Wiring Diagram 10 kW with 1 3 HP motor...

Page 13: ...13 FIGURE 7 Wiring Diagram 15 kW with 1 3 HP motor...

Page 14: ...14 FIGURE 8 Wiring Diagram 18 and 20 kW with 1 3 HP motor and 20 kW with 1 0 HP...

Page 15: ...15 FIGURE 9 Wiring Diagram 23 kW with 1 3 HP and 1 HP motor...

Page 16: ...16 FIGURE 10 Wiring Diagram 27 kW with 1 HP motor...

Page 17: ...COMPONENTS AND REMPLACEMENT PARTS 17...

Page 18: ...18 PARTS LIST Exploded View B50002F Please refer to Table 4 p 20...

Page 19: ...HP 12 B03288 MOUNTING PLATE FOR ELECTRICAL TOP 13 B03289 MOUNTING PLATE FOR ELECTRICAL SIDE 14 L05F004 TERMINAL STRIP 4 POSITION 15 L01H009 RELAY SPDT 24 VAC 16 L01F009 TRANSFORMER 120 24Volts 17 L99...

Page 20: ...7 305891 R02N016 305891 R02N016 305136 R02N017 305136 R02N017 18C 3 305136 R02N017 305891 R02N016 305891 R02N016 305891 R02N016 18D 4 305891 R02N016 305136 R02N017 18E 5 305891 R02N016 Item TABLE 4 FE...

Reviews: