5 Commissioning the system – Procedure
96
5.
To access the respective parameter group, select the group using
the
Up
or
Down
buttons.
6.
Confirm the selected group with the
Enter
button.
✓
The display changes to the selected group.
7.
Use the
Menu
button to leave the selected group.
S
WITCHING
TO
AUTOMATIC
MODE
1.
Using the
Mode
button, switch the control to
AUTOMATIC
opera-
tion.
✓
The
AUTOMATIC
symbol flashes on the control unit.
2.
Press the
Enter
button.
✓
The mode has been changed.
✓
The
AUTOMATIC
symbol lights up on the control unit.
The following boiler program will run in automatic mode:
F
ILLING
The delivery system, stoker auger and flue gas fan are switched on.
I
GNITION
The ignition fan and flue gas fan are switched on.
H
EATING
-
UP
The delivery system, stoker auger and flue gas fan are switched on.
C
ONTROL
The delivery system, stoker auger and flue gas fan are switched on.
B
URN
OUT
The flue gas fan is switched on. Enabled for the following:
•
switching to
OFF
mode
•
boiler preset temperature reached, or
•
malfunction occurred.
A
DAPTING
PARAMETERS
If the heating system does not work correctly, the parameters in the
service level must be adjusted accordingly.
✎
See the chapter entitled “6 Using the heating system”, section
“6.10 Structure of the menus”.
Enter
Menu
Enter
Summary of Contents for Compact 25
Page 1: ...hdg bavaria com HDG Compact 25 80 Operation Manual ...
Page 2: ......
Page 186: ...12 Index 186 HDG Compact 25 35 Version 2 de HDG Bavaria GmbH Oktober 2007 ...
Page 187: ......