6 Using the heating system – Structure of the menus
117
1-10
Serial port
Status display
DAQ HCR0
DAQ HCR1
GSM module
Remote maintenance
•
Serial interface
For switching functions.
1-11
General information
Mobile phone
number
•
Mobile phone number
For entry of the operator's mobile phone number for the
setting
GSM module
(
1-10
).
1-17
General information
Correction voltage
Lambda sensor
[mV]
( 0.0)
0.0
•
Correction voltage for lambda sensor
Manual readjustment of the lambda sensor voltage.
1-18
General information
Correction voltage
Lambda sensor max [mV]
( 3.0)
3.0
•
Maximum correction voltage for lambda sensor
Maximum correction voltage for the lambda sensor at
calibration
1-19
General information
Correction voltage
Lambda sensor min [mV]
( -6.0)
-6.0
•
Minimum correction voltage for lambda sensor
Minimum correction voltage for the lambda sensor at
calibration
1-20
General information
Comb.chamb.temp. for
calibrating lambda
( 50)
50°
•
Combustion chamber temperature for calibrating
lambda
Set the combustion chamber temperature for calibrating
the lambda sensor.
(40 - 800 °C)
1-23
Boiler type
C25
C35
C50
C65
C80
•
Boiler type
Selection of the boiler type.
1-24
Language
D - German
GB - English
NL - Dutch
FR - French
•
Display language
Setting the language of the display.
1-25
Power supply
3x400V/N
3x230V
1x230V
1x230V R
•
Supply voltage
Selection of the supply voltage.
No.
Display
Description
Table 6/3 - System level / 1 - General
Summary of Contents for Compact 25
Page 1: ...hdg bavaria com HDG Compact 25 80 Operation Manual ...
Page 2: ......
Page 186: ...12 Index 186 HDG Compact 25 35 Version 2 de HDG Bavaria GmbH Oktober 2007 ...